How many porta potties do I need per person?
For a wedding or party of 100 to 250 guests, a county health department table calls for 2 to 4 portable toilets, depending on how many hours it runs, and one more if alcohol is served. For a job site, OSHA requires 1 toilet for up to 20 workers, then 1 per 40. As a flat rule of thumb, the City of Seattle recommends 1 toilet per 100 people.
Every number comes from an official table, linked below. The calculator rounds up.
How many do I need?
From official tables, rounded up
Portable toilets needed
4
County health department table: up to 250 people for 6 hours, serviced once a day.
Plan at least 1 ADA accessible unit and 1 hand washing station.
Event table: portable restrooms by guests and hours
Serviced once a day. Guests and hours round up to the next row and column.
| People | 2 hours | 4 hours | 6 hours | 8 hours | 10 hours |
|---|---|---|---|---|---|
| 50 | 1 | 1 | 2 | 2 | 2 |
| 100 | 2 | 2 | 3 | 3 | 3 |
| 250 | 3 | 3 | 4 | 4 | 4 |
| 500 | 4 | 4 | 6 | 8 | 8 |
| 1,000 | 5 | 7 | 8 | 8 | 9 |
| 5,000 | 23 | 32 | 36 | 39 | 40 |
| 7,000 | 32 | 45 | 51 | 54 | 57 |
| 10,000 | 46 | 64 | 72 | 77 | 81 |
Source: Hood River County Environmental Health, Event Restroom Estimations, Table I. The same document has a higher table for events with alcohol, which the calculator uses when you tick that box. It also notes that more restrooms are needed if over half of guests are women.
Large events and festivals
Health departments set their own counts for public gatherings. Salt Lake County, Utah, for example, requires these minimums by peak crowd and average hours on site:
| Peak crowd | 1 hour | 4 hours | 8 hours |
|---|---|---|---|
| 500 | 2 | 5 | 9 |
| 1,000 | 4 | 8 | 12 |
| 2,000 | 5 | 12 | 20 |
| 5,000 | 12 | 25 | 50 |
| 10,000 | 15 | 50 | 100 |
Source: Salt Lake County Health Department, Temporary Mass Gathering Application. The same rules add 40 percent more toilets when alcohol is served, one hand wash station per 10 toilets, at least one accessible toilet, and pumping at least every 24 hours.
Job sites
The OSHA minimum
Federal construction rules set a minimum number of toilets by how many workers are on site. A standard portable toilet has one seat and one urinal. The minimum is 1 toilet for 20 or fewer workers, 1 seat and 1 urinal per 40 workers from 20 up, and 1 per 50 from 200 up. OSHA 29 CFR 1926.51(c), Table D-1.
What a county plans instead
A county health department table for building sites serviced once a week plans more: 1 restroom per 10 people up to 50, then 1 more per 10. Source. For a crew of 40 that is 4 units where OSHA asks for 1, so the two answers are a floor and a comfortable number rather than a disagreement. Prices on the construction site page.
Accessible units
At least 5 percent of portable toilets in each cluster must be accessible, so every cluster needs at least one. U.S. Access Board guide. See ADA porta potty rental for prices.
Rule of thumb: Seattle special events recommends one toilet per 100 people.
What changes the number
Six things move the count in the official tables. Headcount is only the first of them.
Hours on site
The tables count hours as well as guests. For 500 guests the Hood River table runs from 5 units at 2 hours to 9 at 10 hours.Alcohol
Every official table here treats it separately. Salt Lake County states it as a flat uplift: “If alcohol is served, the operator shall increase the number of required toilets by 40%.”Who is in the crowd
Hood River County notes that more restrooms are needed if over half of guests are women, because the tables assume a mixed crowd.Service frequency
The event table assumes servicing once a day. With no service visit during a multi-day event, the counts in it no longer hold and you need more units.Accessible units
Five percent of each cluster, rounded up, never fewer than one. This sits on top of the count, not inside it.Hand washing
“A minimum of one hand wash station per 10 toilets or portion thereof shall be provided.” Priced on the hand washing station page.
Common questions
How many porta potties do I need for 100 guests?
For 100 guests, the Hood River County health department table calls for 2 portable restrooms for an event of up to 4 hours and 3 for 6 to 10 hours, serviced once a day. With alcohol served, add one: 3 for up to 4 hours, 4 for longer.
How many porta potties do I need for 200 or 250 guests?
The same table lists 3 restrooms for up to 250 people for up to 4 hours, and 4 for 6 to 10 hours. With alcohol: 4 and 5.
Does alcohol change how many I need?
Yes. Guests who drink use restrooms more often. The Hood River County table adds about one unit at small events, and the Salt Lake County Health Department requires 40 percent more toilets when alcohol is served at a mass gathering.
How many ADA porta potties do I need?
Under the 2010 ADA Standards, at least 5 percent of the portable toilets in each cluster must be accessible, which means at least one accessible unit in every cluster.
Is there a simple rule of thumb?
The City of Seattle's special events office recommends one toilet for every 100 people. The tables above are more precise because they also count hours and alcohol.
Get prices for the number you need
Published ranges are a starting point. The price you pay depends on your ZIP, dates, access and how often the units are serviced, so the fastest way to a real number is a quote.
- One short form, about a minute
- Your request goes to rental companies that serve your ZIP
- Free to ask, no obligation to book